Who are we ? Contact Us
[English] Langue FrançaiseEnglish language
Secodi Distributeur Moteurs Perkins
AGP
Moteur Perkins
Articles' list

Coolant specification

The quality of the coolant which is used can the a great effect on the efficiency and life of the cooling System. The recommendations indicated below can help to maintain a good cooling system and to protect it against frost and/or corrosion.

If the correct procedures are no! used, Perkins cannot be held responsible for frost or corrosion damage.

  1. If it is possible, use clean soft water in the coolant.
  2. If an antifreeze mixture, other than Perkins POWERPART, is used to prevent frost damage, it must have an ethanediol base {ethylene glycol) with a corrosion inhibitor. It is recommended that the corrosion inhibitor is of the sodium nitrite or sodium benzoate type. The antifreeze mixture must be an efficient coolant at ail ambient temperatures and it must provide protection against corrosion. It must also have a specification at least as good as the requirements of the standards below:
  3. United Kingdom: BS.6580:MOD AL39:

    "Specification for corrosion inhibiting, engine coolant concentrate (antifreeze)".

    Perkins POWERPART antifreeze exceeds the requirements of the above standards.

    The quality of the antifreeze coolant must be checked at least once a year, for example, at the beginning of the cold period. Renew the coolant every two years.

    The antifreeze mixture must consist of equal quantities of antifreeze and water. Concentrations of more than 50% of antifreeze must not be used because these can affect adversely the performance of the coolant

  4. When frost protection is not necessary, it is still an advantage to use an approved antifreeze mixture because this gives a protection against corrosion and also raises the boiling point of the coolant.
  5. If an antifreeze is not used, add a correct mixture of corrosion inhibitor to the water.

    Renew the mixture of water and corrosion inhibitor every six months or check it according to the inhibitor manufactures recommendations.

    Caution: Certain corrosion inhibitor mixtures could cause damage to some engine components. It is recommended that you consult the Perkins Engines Company Limited, Peterborough if a corrosion inhibitor is to be used.